Case Report A Sheared Catheter Fragment in the Wrist after Arterial Cannulation Attempt: A Case Report
Sue Young Lee, Hyo Seok Na, Mi Hyun Kim, Chong Soo Kim, Young Tae Jeon, Jung Won Hwang, Sang Hwan Do

DOI: https://doi.org/10.4266/kjccm.2010.25.2.118
  • 2,247 Views
  • 24 Download
  • 3 Crossref
  • 0 Scopus
1Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam, Korea. shdo@snu.ac.kr
2Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, Korea.
3Department of Anesthesiology and Pain Medicine, Seoul National University Boramae Medical Center, Seoul, Korea.

Citations

Citations to this article as recorded by  Crossref logo
  • Fracture of an Intravenous Cannula in the Hand: A Case Report
    Seungho Woo, Sangun Nah, Giwoon Kim, Sangsoo Han
    Journal of Emergency Nursing.2023; 49(2): 156.     CrossRef
  • Iatrogenic catheter sheath shearing during radial artery cannulation
    Il-Seok Kim, Ho Kyun Shin, Dae Yu Kim
    Korean Journal of Anesthesiology.2013; 65(6 Suppl): S12.     CrossRef
  • A retained catheter fragment in radial artery caused by accidental catheter transection during arterial catheter removal
    Seung-Ki Moon, Jae-Chul Gong, Jun-Hyun Kim, Kyu Chang Lee, Hye Young Kim, Eun Kyung Choi, Myeong Jong Lee
    Journal of Anesthesia.2012; 26(4): 625.     CrossRef