Dear Editor:
I found Professor Lee’s article on blood gas monitoring in this issue of the Journal [1] both insightful and thought-provoking. One of the key takeaways was the emphasis on mixed venous blood as a more representative indicator of global tissue oxygen consumption and metabolic status compared to central venous oxygen saturation (ScvO₂). Professor Lee rightly highlighted several confounding factors affecting ScvO₂, including the possibility of elevated ScvO₂ levels in the context of reduced systemic oxygen consumption, which may mask inadequate oxygen delivery. The suggestion to interpret ScvO₂ alongside the venous-to-arterial CO₂ difference (∆pv-aCO₂) adds valuable nuance to clinical decision-making during resuscitation.
In our previous research, we identified four predictors of occult tissue hypoperfusion associated with increased tissue oxygen extraction: ∆pv-aCO₂, arterial pH, hemoglobin concentration, and lactate levels. Among these, ∆pv-aCO₂ emerged as the most significant, with an odds ratio of 4.41 per mm Hg increase (95% CI, 1.7–11.2; P=0.002), accounting for approximately 34% of the variability in hypoperfusion risk [2].
I fully concur with Professor Lee’s conclusion that no single hemodynamic parameter—whether static or dynamic—can provide a complete picture. Each metric offers unique insights but also carries inherent limitations [3]. A common misconception is that the balance between oxygen delivery and consumption solely determines ScvO₂ or mixed venous oxygen saturation [4]. In reality, venous oxygen tension governs saturation levels, not vice versa. While increases in arterial oxygen tension (PaO₂) may only slightly elevate venous oxygen tension, this modest change can significantly impact ScvO₂ due to the steep slope of the oxygen-hemoglobin dissociation curve (Figure 1).
Therefore, interpreting ScvO₂ as a reflection of cardiac output or oxygen delivery is only valid when PaO₂ remains constant. A seemingly adequate ScvO₂ may not indicate sufficient systemic oxygen delivery if elevated PaO₂ is not ruled out [4]. Moreover, the influence of high PaO₂ or excessive inspired oxygen (FiO₂) extends beyond ScvO₂. Jugular bulb venous oxygen saturation and brain tissue oxygen tension (BtO₂) can also rise by over 10% solely due to increased PaO₂ [5]. Thus, when evaluating ScvO₂, jugular bulb saturation, or BtO₂—especially their temporal changes—PaO₂ must be considered to avoid misinterpretation.
NOTES
-
CONFLICT OF INTEREST
No potential conflict of interest relevant to this article was reported.
-
FUNDING
None.
-
ACKNOWLEDGMENTS
None.
-
AUTHOR CONTRIBUTIONS
All the work was done by Kwok Ming Ho.
Figure 1.Impact of inspired oxygen concentration and arterial oxygen tension on venous oxygen tension. The blue dotted line indicates the venous oxygen tension (mm Hg) and venous oxygen saturation (%) at baseline; and the red dotted line indicates a possible large increment in venous oxygen saturation (%) even with a small increment in venous oxygen tension (mm Hg) when a higher inspired oxygen concentration is used compared to baseline.
REFERENCES
- 1. Lee GR. Clinical applications of blood gas analysis: a comparative review of arterial and venous blood gas monitoring in critical care. Acute Crit Care 2025;40:153-9.ArticlePubMedPMCPDF
- 2. Silbert BI, Litton E, Ho KM. Central venous-to-arterial carbon dioxide gradient as a marker of occult tissue hypoperfusion after major surgery. Anaesth Intensive Care 2015;43:628-34.ArticlePubMedPDF
- 3. Ho KM. Pitfalls in haemodynamic monitoring in the postoperative and critical care setting. Anaesth Intensive Care 2016;44:14-9.ArticlePubMedPDF
- 4. Ho KM, Harding R, Chamberlain J. The impact of arterial oxygen tension on venous oxygen saturation in circulatory failure. Shock 2008;29:3-6.ArticlePubMed
- 5. Legrand M, Vallée F, Mateo J, Payen D. Influence of arterial dissolved oxygen level on venous oxygen saturation: don't forget the PaO2! Shock 2014;41:510-3.ArticlePubMed
Citations
Citations to this article as recorded by