Abstract
-
Background
- Resting energy expenditure (REE) estimation is crucial in critically ill patients. While indirect calorimetry (IC) is the gold standard, its limited availability often necessitates alternative methods. In this exploratory study, we compared the accuracy of the stress factor-corrected Harris-Benedict (cREEHB) and weight-based (REEWB) equations with the Weir equation (REEW) using oxygen consumption (VO₂) and carbon dioxide production (VCO₂) estimated via the Fick principle.
-
Methods
- We included patients admitted to the intensive care unit (ICU) between January and August 2024, and computed cREEHB, REEWB (22.5 kcal/kg/day), and REEW. Agreement between methods was assessed through Bland-Altman analysis. Sensitivity and correlation analyses identified bias determinants. Multiple linear regression explored associations of REEW with VO₂, VCO₂, and cardiac output (CO).
-
Results
- The sample size consisted of 30 patients. No correlation was found between REEW and cREEHB (r=0.177, P=0.349) or REEWB (r=-0.006, P=0.975). Compared to REEW, cREEHB underestimated REE (mean bias, –47.9 kcal), while REEWB overestimated it (mean bias, +9.7 kcal). CREEHB bias was associated with sex, height, body surface area (BSA), VO2, and respiratory quotient (RQ); REEWB bias was influenced by actual body weight, body mass index, BSA, VO2, and RQ (all P<0.05). Multiple linear regression analysis showed that REEW was influenced by VO2 (P<0.001) and VCO2 (P<0.001) but not by CO (P=0.164).
-
Conclusions
- Predictive equations may not be interchangeable in ICU settings, leading to inaccurate metabolic assessments. Studies incorporating IC as a reference are needed to determine the most reliable approach for estimating REE and optimizing nutritional support in critical patients.
-
Key Words: Fick equation; Harris-Benedict; nutritional support; resting energy expenditure; Weir equation
INTRODUCTION
Estimating resting energy expenditure (REE) in critically ill patients is a key component for managing nutritional needs. Adequate nutrition has been shown to reduce complications, improve outcomes, and promote recovery in the intensive care unit (ICU) [1]. Guidelines recommend indirect calorimetry (IC) as the “gold standard” for determining REE [2]. IC accurately estimates REE, particularly in critically ill patients whose metabolic needs constantly shift. The method allows a tailored approach to nutritional management and ensures the appropriate amount of calories based on patient condition. The oxygen consumption (VO2) and carbon dioxide production (VCO2) obtained by IC are used in the Weir equation to determine REE [3]. However, IC use is often constrained by costs, technical difficulties, and the need for trained personnel. Moreover, IC measurements are generally performed over 1–2 hours per day and under controlled conditions, not accounting for daily variation [4,5].
As a result, predictive equations, such as the Harris-Benedict (HB) equation, are widely used as substitutes when IC is not available [6,7]. The HB formula relies on static variables such as age, gender, weight, and height to estimate caloric needs and is a convenient and accessible tool in clinical practice. Therefore, HB remains a commonly used reference in many institutions, including ours. However, its accuracy in critically ill patients has been debated [8,9]. Despite the development of stress-corrected versions of the original HB formula, critical illness is associated with profound alterations in metabolism due to inflammation, infection, organ failure, and mechanical ventilation, which are not adequately captured by static models. Consequently, reliance on predictive equations can result in significant discrepancies between estimated and actual REE, potentially leading to underfeeding or overfeeding, both associated with adverse clinical outcomes [10,11]. In recognition of these limitations, current guidelines also suggest the use of simple weight-based equations (such as 20–25 kcal/kg/day) to approximate caloric requirements when IC is unavailable [2]. While practical, this approach may further oversimplify the estimation of REE in metabolically heterogeneous ICU populations.
The Fick equation represents an interesting alternative to computing VO2 and VCO2 by relating cardiac output (CO) to the difference in the arterial-venous contents of O2 and CO2 obtained from blood gas analysis. This allows reliable VO2 and VCO2 estimations without resorting to the IC and overcomes the limits related to predictive or weight-based equations [12,13]. However, studies exploring this alternative approach and its relationship with the HB or weight-based equations are lacking [14].
The primary objective of this exploratory retrospective analysis was to assess the relationships between three methods for REE estimation in critically ill patients: the stress-factor-corrected HB, weight-based HB, and the Weir equations based on surrogate VO₂ and VCO₂ values calculated using the Fick method. As a secondary objective, we aimed to identify clinical and demographic variables influencing the bias between predictive and measured estimates. Finally, we investigated the associations between REE derived via the Weir-Fick method and key physiological parameters, including CO, VO2, and VCO2.
MATERIALS AND METHODS
For this explorative retrospective study, we enrolled patients admitted to the ICU from January to August 2024. Data were anonymously collected. The study was conducted following the International Conference on Harmonization Good Clinical Practice guidelines, the 2008 Declaration of Helsinki provisions, and the STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) guideline. The local Ethics Committee (Campania 2) approved the study (ID 2025/3337) and waived the requirement for informed consent in view of its retrospective and observational nature. All patients were managed within the scope of routine clinical practice.
On admission, the following variables were collected: sex, age, height, weight, main comorbidities, reasons for ICU admission, Glasgow Coma Scale (GCS), Sequential Organ Failure Assessment (SOFA) Score, and Simplified Acute Physiology Score (SAPS) II [15-17]. Body mass index (BMI) and body surface area (BSA; using the Mosteller formula) were computed, and obesity was defined as BMI ≥30.0 kg/m2.
Exclusion Criteria CriteriaThe exclusion criteria for REE computation were (1) need for vasopressors and inotropic agents within 48 hours before measurement; (2) fever or hypothermia within 48 hours before measurement; (3) use of neuromuscular blocking agents at the time of measurement due to patient–ventilator asynchrony not correctable by sedation alone; (4) continuous renal replacement therapy; (5) arrhythmia; and (6) unstable plethysmographic SpO2 curve signal.
REE Computation
All patients were sedated and mechanically ventilated prior to measurement. Sedation protocols included continuous infusion of propofol and/or midazolam, combined with opioids (mainly remifentanil), as per institutional standards. The target level of sedation was a Richmond Agitation-Sedation Scale score between –2 and –3.
For every patient, we performed one computation. REE was computed using the HB, weight-based, and Weir equations. For HB REE (REEHB) estimation, we used the following formula [6]:
Male REE=88.362+(13.397×weight (kg))+(4.799×height (cm))–(5.677×age)
Female REE=447.593+(9.247×weight (kg))+(3.098×height (cm))–(4.33×age)
When BMI < 30.0 kg/m2, we used actual body weight (AcBW), while other cases used adjusted body weight (AdBW), computed as ideal body weight (IBW) plus 33.3% of the difference between AcBW and IBW [2,18]. The REEHB was corrected (cREEHB) by multiplying its value by a stress factor: 1.10 for elective surgery, 1.25 for complicated surgery, and 1.25–1.50 for sepsis or trauma conditions.
For weight-based REE (REEWB) estimation, we assumed a caloric requirement of 22.5 kcal/kg/day, the midpoint of the guideline-recommended range of 20–25 kcal/kg/day [2]. The same body weight criteria (AcBW vs. AdBW) described above were applied for this calculation.
For Weir REE (REEW) estimation, we used the following formula [3]:
REEW=1.44×[(3.94×VO2)+(1.11×VCO2)]
For that, VO2 and VCO2 were indirectly estimated with the Fick Equation, using values obtained from blood gas analysis and hemodynamic monitoring [12,13].
Venous and arterial blood samples were obtained using a central venous line placed in the internal jugular or subclavian vein and an arterial catheter placed in the non-dominant side radial artery. Before sampling, 5 mL were discharged from the line. An in-situ blood gas analyzer analyzed venous and arterial samples (GEM PREMIER 5000). Hemoglobin (Hb) concentration was obtained by laboratory testing with a venous blood sample before REE measurement. The following parameters were noted: arterial (PaO2) and venous partial O2 pressure (PvO2), venous (SvO2) and arterial O2 saturation (SaO2), arterial (PaCO2) and venous partial CO2 pressure (PvCO2), and blood bicarbonate (HCO3-) concentration.
Using these variables, we computed
Arterial O2 content (CaO2)=(SaO2×Hb×1.34)+(PaO2×0.03)
Venous O2 content (CvO2)=(SvO2×Hb×1.34)+(PvO2×0.03)
Venous CO2 content (CvCO2)=(PvCO2×0.03)+venous HCO3-
Arterial CO2 content (CaCO2)=(PaCO2×0.03)+arterial HCO3-
CO was computed using the minimally invasive estimated Continuous Cardiac Output (esCCO; Nihon Kohden) based on pulse wave transit time (PWTT) [19,20]. PWTT is defined as the period between the peak of the wave R of the ECG and the beginning of the ascending phase of the SpO2 plethysmographic curve. The SpO2 probe was placed on a finger, free from arterial and venous lines to avoid bias.
The VO2 and VCO2 were computed as
VO2 (ml/min)=CO×(CaO2–CvO2)
VCO2 (ml/min)=CO×(CvCO2–CaCO2)
Then, the respiratory quotient (RQ) was computed.
Statistical Analysis
Continuous variables were tested for normal distribution with the Shapiro-Wilk test and reported as mean±standard deviations (SDs) or medians, first and third quartiles (Q1–Q3), and ranges. Categorical variables were reported as absolute numbers and percentages (%). According to our primary aim, we analyzed the correlations between REEW, cREEHB, and REEWB, with REEW as the reference method. We computed the Pearson correlation coefficient (r) with a 95% CI. We performed simple linear regression analysis and calculated the coefficients of determination (R2). We performed Bland-Altman analysis and computed bias, upper and lower limits of agreements (uLoA and lLoA), and 95% CI [21].
Our secondary aim was to identify factors influencing bias, for which we performed a sensitivity analysis. For categorical variables (sex, obesity, and admission for trauma), the difference in bias value was evaluated with Student t-test (Welch test in the case of heteroscedasticity) or Mann-Whitney test when appropriate. For continuous variables (age, BMI, BSA, CO, PaO2, PvO2, PaCO2, PvCO2, SaO2, SvO2, arterial and venous HCO3–, Hb, CaO2, CvO2, CaCO2, CvCO2, VO2, VCO2, RQ), r or Spearman (ρ) coefficients, with 95% CI, were computed according to data distribution (evaluated with the Shapiro-Wilk test). The strength of the relationship was defined as very weak (r/ρ ≤0.1), weak (0.1 < r/ρ ≤0.3), moderate (0.3< r/ρ ≤0.5), strong (0.5< r/ρ ≤0.7), or very strong (r/ρ >0.7) [22].
For the third objective, we analyzed the relationships of REEW with CO, VO2, and VCO2. For each variable, normality was tested using the Shapiro-Wilk test to determine the appropriate correlation coefficient (r or ρ). Correlation coefficients were reported along with 95% CI and associated P-values. To further explore independent associations, we performed multiple linear regression analyses with REEW as the dependent variable and CO, VO2, and VCO2 as explanatory variables. We calculated the standardized beta (β) coefficients, standard errors (SEs), and adjusted R2. Multicollinearity was assessed using the variance inflation factor (VIF).
Statistical analysis was computed using R-Studio (R Core Team 2024; R Foundation for Statistical Computing, https://www.R-project.org/). All tests were performed with α=0.05. A P-value <0.05 was considered significant. Results are reported in tables and plots.
RESULTS
Descriptive Statistics
Our sample consisted of 30 patients (Table 1). Briefly, 24 patients (80.0%) were male, the mean age was 60.6 years (SD, 14.4), and the mean BMI was 26.1 kg/m2 (SD, 5.3). Seven patients (23.3%) required ICU admission for trauma. The median GCS, SAPS II, and SOFA scores were 5.0, 65.0, and 11.0, respectively. The most common comorbidities were hypertension (18 patients, 60.0%), diabetes (6 patients, 20.0%), obesity (5 patients, 16.7%), and COPD (5 patients, 16.7%). REEHB showed a mean of 1473.0 kcal (SD, 203.7; range, 1,052.0–1,796.0). The correction factor was applied in four patients (13.3%), and the REEHB correction factor was 1.25 in three patients and 1.5 in one patient. The mean cREEHB was 1533.0 kcal (SD, 257.5; range, 1,052.0– 2,055.0), that of the REEW was 1581.0 kcal (SD, 160.6; range, 1,315.0–1 ,930.0), and that of the REEWB was 1590.0 kcal (SD, 225.7; range, 1,012.0–1,935.0). Table 2 shows the results of the parameters used to compute REEW.
Correlation and Bland-Altman Analysis
Thirty data pairs were obtained. There was no significant relationship between REEW and cREEHB (r=0.177; 95% CI, –0.196 to 0.505; R2=0.031, P=0.349) (Figure 1A) or REEW and REEWB (r=–0.006; 95% CI, –0.365 to 0.355; R2=0.000, P=0.975) (Figure 1B). The Bland-Altman analysis (Figure 1C) showed that cREEHB underestimated REE compared to REEW, with a mean bias of –47.9 kcal (SD, 278.3 kcal; 95% CI, –151.8 to 56.0 kcal), which was not significant (P=0.354). The values of uLoA and lLoA were 497.5 kcal (95% CI, 317.9 to 677.1 kcal) and –593.3 (95% CI, –772.9 to –413.7 kcal), respectively. In contrast, REEWB (Figure 1D) overestimated REE compared to REEW, with a mean bias of +9.7 kcal (SD, 277.8 kcal; 95% CI, –94.0 to 113.5 kcal), which was not significant (P=0.849). The respective values of uLoA and lLoA were 554.2 kcal (95% CI, 374.9 to 733.5 kcal) and –534.8 (95% CI, –714.0 to –355.5 kcal).
Sensitivity Analysis
Regarding bias between cREEHB and REEW, females and males showed a mean bias of –222.9 kcal (SD, 188.1 kcal) and –4.1 kcal (SD, 282.8 kcal), respectively, with statistically significant difference (Welch test P=0.043). Non-obese and obese patients showed a mean bias of –27.4 kcal (SD, 285.7 kcal) and –150.2 kcal (SD, 236.4 kcal), respectively, with no significance (Welch test P=0.343). Patients admitted to the ICU for trauma showed a mean bias of 99.1 kcal (SD, 205.7 kcal), while the bias for patients admitted to the ICU for other reasons was –92.6 kcal (SD, 285.6 kcal). Difference was not significant (Welch test P=0.071). Regarding bias between REEWB and REEW, no differences were noted for sex (mean±SD, –36.3±102.9 kcal in females vs. 21.2±307.1 kcal in males, Welch test P=0.453), obesity (mean±SD, 13.1±293.2 kcal in non-obese vs. –7.0±216.7 kcal in obese patients; Welch test P=0.864), and admission for trauma (mean±SD, –19.2±304.4 in patients admitted for other reasons vs. 104.7±139.8 kcal in patients admitted for trauma; Welch test P=0.147).
Table 3 showed the correlation coefficients between bias and continuous variables. Regarding bias between cREEHB and REEW, height, BSA, VO2, and RQ showed significant relationships. BSA showed a strong positive relationship (r=0.513; 95% CI, 0.188 to 0.737; P=0.004) (Figure 2A), while height (r=0.429; 95% CI, 0.081 to 0.684; P=0.018) (Figure 2B) and RQ (ρ=0.409; 95% CI, 0.010 to 0.806; P=0.025) (Figure 2C) showed a moderate positive relationship. Despite AcBW showing a moderate positive relationship, the results were not significant (r=0.351; 95% CI, –0.011 to 0.631; P=0.057). Finally, VO2 showed a moderate negative relationship (r=-0.436; 95% CI, –0.688 to –0.089; P=0.016) (Figure 2D).
Regarding bias between REEWB and REEW, AcBW, BMI, BSA, VO2, and RQ showed significant relationships. Strong positive relationships were found for aBW (r=0.594; 95% CI, 0.299 to 0.787; P<0.001) (Figure 3A), BSA (r=0.660; 95% CI, 0.393 to 0.824; P<0.001) (Figure 3B), and RQ (r=0.581; 95% CI, 0.305 to 0.853; P<0.001) (Figure 3C), while VO2 showed a strong negative relationship (r=–0.628; 95% CI, –0.806 to –0.347; P<0.001) (Figure 3D). BMI showed a moderate positive relationship with bias (r=0.402; 95% CI, 0.049 to 0.666; P=0.027) (Figure 3E). Despite PaO2 showing a moderate negative relationship, the results were not significant (r=–0.337; 95% CI, –0.622 to 0.026; P=0.068).
Multiple Linear Regression Analysis
CO showed a weak positive non-significant relationship with REEW (r=0.173; 95% CI, –0.200 to 0.502; P=0.361) (Figure 4A). In contrast, VO2 and VCO2 showed, respectively, a very strong (r=0.981; 95% CI, 0.959 to 0.991; P<0.001) (Figure 4B) and strong (r=0.650; 95% CI, 0.379 to 0.819; P<0.001) (Figure 4C) significant positive relationship with REEW. Multiple linear regression analysis showed that REEW was influenced by VO2 (β=5.68, SE=0.02, P<0.001) and VCO2 (β=1.55, SE=0.02, P<0.001) but not by CO (β=–0.59, SE=0.41, P=0.164). No relevant collinearity was observed (VIF for CO, VO2, and VCO2 was 1.12, 1.46, and 1.40, respectively). The overall model P-value was <0.001 with an adjusted-R2=0.999.
DISCUSSION
In this exploratory study, we compared two predictive approaches for estimating REE, the cREEHB and REEWB, with the REEW equation using VO2 and VCO2 derived from the Fick method. Our findings suggest that both predictive methods showed limited correlation with REEW. Although the corrected HB equation tended to underestimate REE and the weight-based approach slightly overestimated it, these differences were not significant. Nevertheless, Bland-Altman analysis revealed a wide LoA for both comparisons, highlighting a relevant degree of individual variability. These observations underline the importance of cautious interpretation when relying on predictive methods for REE assessment in ICU patients. Our results are consistent with prior literature highlighting the limitations of predictive equations for REE in critically ill, mechanically ventilated patients. Although IC is the gold standard for REE measurement, its limited availability often leads clinicians to rely on predictive methods [2].
Several studies have shown that these formulas can produce substantial inaccuracies. For instance, Zusman et al. [23] reported that predictive equations may deviate from measured REE by up to 60%, while De Waele et al. [24] emphasized that HB and Penn State formulas tend to either overestimate or underestimate REE, particularly in elderly or obese individuals. Hunter et al. [25] also found low correlations between measured and predicted REE values in ventilated patients. Interestingly, they proposed that predictive performance might improve by incorporating variables such as body composition and physiological stress markers.
In our study, we attempted to correct the HB equation by applying stress factors tailored to clinical condition. However, findings in the literature on this approach remain mixed. MacDonald and Hildebrandt [26] suggested a stress factor (e.g., 1.6) to achieve predictive equations sufficiently accurate for short-term use in ICU settings, while Japur et al. [27] reported that adjusted HB estimates were reasonably reliable. In contrast, Hunter et al. [25] did not confirm these results, further underscoring the inconsistency of outcomes.
Finally, systematic reviews and meta-analyses have reiterated the poor clinical performance of predictive equations compared to measured REE, particularly in heterogeneous ICU populations [8,9]. The inaccuracy stems in part from the use of weight as a proxy variable, which can be difficult to assess reliably in critically ill patients and is influenced by fluid shifts, edema, or muscle loss [28]. Consequently, these tools may lead to underfeeding or overfeeding, both associated with worsened clinical outcomes.
Consistent with current guidelines [2], in the absence of IC or VO₂/VCO₂ measurements, simple weight-based equations (such as 20–25 kcal/kg/day) may represent a pragmatic and widely available option. While less tailored, their ease of use explains their frequent application in clinical practice. In our analysis, we used an intermediate value (22.5 kcal/kg/day) within the recommended range. Interestingly, compared to REEW, REEWB showed a limited average bias, suggesting reasonable alignment at the population level. Despite this average agreement, Bland-Altman analysis demonstrated wide limits of agreement, indicating that individual predictions can vary substantially. These findings align with previous studies, which underline the over- or underestimation of REE weight-based equations depending on the population and clinical context. Rousseau et al. showed that the 30 kcal/kg/day formula significantly overestimated REE in post-ICU survivors, with measured REE averaging around 22.9 kcal/kg/day [29]. Conversely, Smetana et al. reported that the 25 kcal/kg/day equation tended to underestimate energy needs in critically ill stroke patients, especially in those with intracerebral hemorrhage or subarachnoid hemorrhage, whereas the 30 kcal/kg/day formula offered closer estimates to IC targets [30]. Altogether, these data support the notion use of weight-based equations should be tempered by awareness of their limitations despite their usefulness in the absence of more advanced techniques. Clinicians should interpret their outputs cautiously and consider clinical context, patient phenotype, and illness phase when applying them to guide nutritional strategies.
Several variables showed significant associations with the bias observed between estimated and measured REE for both cREEHB and REEWB equations. In both cases, BSA showed a strong positive correlation with the bias, suggesting that larger BSA may contribute to overestimation of REE when using simplified formulas. Our results are different from those of Pavlidou et al. [31], who evaluated the agreement between predicted REE and actual measurements from IC. Equations incorporating height, along with other variables like weight, age, and sex, provided more accurate predictions than those using only weight and gender. For both methods, RQ exhibited a positive correlation, while VO₂ showed a strong inverse correlation with bias, which is expected given its direct influence on the measured REE via the Weir formula. Saur et al. [32] showed that VO2 measured during mild therapeutic hypothermia was lower than that predicted by HB estimation, requiring a corrective factor when HB is used without IC.
In addition, sex was a relevant factor, although its impact differed between the two methods. For cREEHB, female patients showed a significantly greater underestimation of REE compared to males. These findings suggest that the HB equation may not accurately capture the metabolic needs of critically ill women. To the best of our knowledge, the relationship between sex and bias among REE estimated methods is not well investigated. Bias can be clinically relevant, as inaccurate caloric intake in female patients could result in inadequate nutritional support, potentially leading to poor outcomes [11,33]. Gender differences can be attributed to variations in body composition, particularly free-fat mass (FFM). Carrasco et al. [34] showed that REE tends to be lower in women than men due to lower FFM. Furthermore, predictive equations like HB often fail to account accurately for these differences, leading to incorrect estimates in REE for women and obese patients. Interestingly, while AcBW and BMI were significantly associated with bias in the REEWB, their correlation with cREEHB bias was weaker, and that of AcBW was not significant. This discrepancy may reflect the influence of structural differences in the equations, as weight plays a more central role in simplified formulas than in HB-based estimations corrected by stress factors.
According to our results, static predictive equations can determine under- or overestimations of REE, especially at the extremes of “normal” distributions curve of physical and metabolic characteristics. The Weir equation is better suited to capturing the dynamic energy requirements of patients with highly variable metabolic activity. This is particularly important in the ICU, where metabolic demands can change rapidly in response to stressors such as sepsis, trauma, and mechanical ventilation. We calculated VO2 and VCO2 using the Fick principle. Although current nutritional guidelines [2] recommend the use of data derived from pulmonary artery catheter (PAC) measurements to estimate VO2 more accurately, this approach is not always feasible in clinical practice due to its invasive nature, limited availability, and patient-specific contraindications. In our cohort, PAC was not routinely used, and data acquisition relied on less invasive methods compatible with standard monitoring. While this limitation may introduce a source of variability, previous evidence supports the validity of this approach. Ong et al. [35] demonstrated that combining Fick-derived VO2 and VCO2 with the Weir equation allowed a reasonably accurate estimation of REE in critically ill patients undergoing venovenous extracorporeal membrane oxygenation for whom IC was not feasible. This pragmatic choice reflects the balance between methodological rigor and real-world applicability, particularly in the heterogeneous ICU setting.
In our study, VO2 and VCO2 were significant and influential predictors of REEW. These findings have substantial implications for clinical practice. The strong relationships of VO2 and VCO2 with REEW indicate that real-time assessment with the Fick equation is highly effective for accurately determining patient energy needs. Contrary to the findings of the literature, CO did not show a significant relationship. Studies highlighted the interconnectedness of CO and REE. Brown and Pearson [36] demonstrated a positive correlation between CO and VO2, providing an early foundation for understanding how variations in CO impact metabolic demands. Peyton [37] further elaborated on the effects of changes in CO, particularly in the context of hemodynamic alterations, on CO2 elimination, confirming that CO2 variations can reflect real CO changes. In our study, the hemodynamic stability and the reduced VO2 related to the use of sedative drugs could partly explain the lack of correlation between CO and REE. According to our findings, given the minimal contribution of CO to the prediction of REE, relying on VO₂ and VCO₂ as primary indicators for caloric needs may lead to better-informed decisions regarding nutritional support and energy supplementation. In our study, CO was computed with esCCO, a less invasive alternative to the traditional thermodilution method. Several studies have demonstrated a moderate to strong correlation between esCCO and thermodilution or PAC-derived CO, with correlation coefficients ranging from 0.6 to 0.84 depending on the clinical setting [38,39]. However, the agreement in absolute values remains variable, with reported biases up to ±1.2 L/min and percentage errors between 18% and 69%. [40,41] While esCCO may underestimate CO in unstable patients or during hemodynamic shifts, it is generally considered suitable for trend monitoring, particularly in hemodynamically stable conditions or when invasive methods are contraindicated [42].
This study presents several strengths. First, to our knowledge, it is among the few analyses to directly compare REE estimated via the corrected HB equation, a standardized weight-based approach, and the Weir equation derived from Fick-based VO2 and VCO2 measurements in a homogeneous cohort of sedated, mechanically ventilated ICU patients. Second, we applied a comprehensive sensitivity analysis to explore patient-specific factors influencing estimation bias, offering novel insights into the performance of predictive formulas across physiological profiles. Third, the method we adopted relies solely on routinely available arterial and central venous blood gas analyses and is feasible even in settings lacking access to advanced monitoring techniques such as PAC or IC.
However, some limitations should be acknowledged. First, we did not directly compare our results with IC, the gold standard for measuring REE. Therefore, our findings should be interpreted cautiously. Second, the retrospective design introduced potential biases, and the small sample size limited the generalizability of the findings, especially on factors influencing bias. Prospective studies allow more controlled data collection and potentially more accurate results, leading to more robust conclusions. Third, the study population may not fully represent all critically ill patients. Specifically, although CO was not significant, its role in specific subpopulations, such as patients with heart failure or severe hemodynamic instability, may be more pertinent. Further studies are needed to explore how CO and other hemodynamic factors influence REE. Fourth, the study relied on a static model, which may not adequately capture the dynamic changes in metabolism in critically ill patients. Variations in patient conditions, treatments, or metabolic stress can affect energy demands. A model that adjusts dynamically over time may yield more accurate predictions. Future research should investigate how time-dependent variables can enhance the model responsiveness to evolving clinical conditions.
In conclusion, our study highlights the limitations of predictive equations in accurately estimating REE in critically ill patients and raises questions about their interchangeability when IC is unavailable. In contrast, the Weir equation, applied using VO2 and VCO2 estimates derived from the Fick method, offers a more customized and dynamic assessment of metabolic demands. This approach benefits from integration of real-time physiological variables and reflects the fluctuating metabolic state of ICU patients more accurately than static formulas. Notably, it requires only data obtained from standard arterial and central venous blood gas analysis and is a minimally invasive and widely applicable alternative even in the absence of advanced monitoring systems. Further research with larger cohorts is needed to refine this method and evaluate its accuracy across phases of critical illness. Incorporating comparisons with IC will also be essential to confirm the clinical validity of VO2 and VCO2 estimates derived from the Fick principle.
KEY MESSAGES
▪ Accurate estimation of resting energy expenditure (REE) is crucial for optimizing nutrition in critically ill patients; while indirect calorimetry (IC) remains the reference standard, it is often unavailable in daily practice.
▪ The stress factor-corrected Harris-Benedict and weight-based equations showed limited agreement with the Weir equation-based results when oxygen consumption (VO₂) and carbon dioxide production (VCO₂) are derived using the Fick method.
▪ Furthermore, several factors influenced bias among methods, impacting the accuracy of predictions.
▪ The use of the Weir equation with minimally invasive Fick-derived gas exchange measurements may offer a more individualized and feasible alternative for estimating REE at the bedside when IC is not accessible.
NOTES
-
CONFLICT OF INTEREST
No potential conflict of interest relevant to this article was reported.
-
FUNDING
None.
-
ACKNOWLEDGMENTS
None.
-
AUTHOR CONTRIBUTIONS
Conceptualization: AC. Methodology: AR, AC, SP (Salvatore Palmese), SP (Sabato Pascarella), BP. Formal analysis: AR, AC, SP (Salvatore Palmese), BP. Data curation: AR. Visualization: AC, SP (Salvatore Palmese), SP (Sabato Pascarella), BP. Project administration: RG. Funding acquisition: RG. Writing - original draft: AR, AC, SP (Salvatore Palmese), SP (Sabato Pascarella), BP, RG. Writing - review & editing: AR, AC, SP (Salvatore Palmese), SP (Sabato Pascarella), BP, RG. All authors read and agreed to the published version of the manuscript.
Figure 1.(A, B) Scatter plots with regression line (red dashed line) and 95% CI (grey area) for Weir resting energy expenditure (REEW) respectively compared to resting energy expenditure computed with the corrected Harris-Benedict equation (cREEHB) and weight-based REE (REEWB). (C, D) The Bland-Altman plots for bias between Harris-Benedict and Weir (C), and weight-based and Weir (D). The blue, red, and green areas represent the 95% CI, for bias, lower limit of agreement, and upper limit of agreement, respectively.
Figure 2.Scatter plots for bias (defined as the difference between resting energy expenditure computed with the corrected Harris-Benedict equation [cREEHB] and Weir resting energy expenditure [REEW]) and body surface area (BSA) (A), height (B), respiratory quotient (RQ) (C), and oxygen consumption (VO2) (D). The red dashed line represents the regression line, while the grey area is the 95% CI.
Figure 3.Scatter plots for bias (defined as the difference between weight-based REE [REEWB] and Weir resting energy expenditure [REEW]) and actual body weight (AcBW) (A), body surface area (BSA) (B), respiratory quotient (RQ) (C), oxygen consumption (VO2) (D), and body mass index (BMI) (E). The red dashed line represents the regression line, while the grey area is the 95% CI.
Figure 4.Scatter plots for cardiac output (CO) (A), oxygen consumption (VO2) (B), and carbon dioxide production (VCO2) (C), with the regression line (red dashed line) and 95% CI (grey area). REEW: resting energy expenditure computed with the Weir equation.
Table 1.Sample characteristics (n=30)
|
Variable |
Value |
Range |
|
Age (yr) |
60.6±14.4 |
20–89 |
|
Sex, male |
24 (30.0) |
- |
|
Height (cm) |
169.4±8.0 |
155.0–190.0 |
|
Actual body weight (kg) |
74.4±13.4 |
45.0–100.0 |
|
BMI (kg/m2) |
26.1±5.3 |
16.5–40.8 |
|
BSA (m2) |
1.8±0.2 |
1.5–2.1 |
|
BMI/BSA (kg/m4) |
14.1±2.3 |
9.9–20.9 |
|
Admission for trauma |
7 (23.3) |
- |
|
GCS |
5.0 (4.0–7.0) |
3.0–13.0 |
|
SAPS II |
65.0 (55.0–78.0) |
34.0–106.0 |
|
SOFA score |
11.0 (8.0–13.0) |
6.0–18.0 |
|
Hypertension |
18 (60.0) |
- |
|
Diabetes |
6 (20.0) |
- |
|
Obesity |
5 (16.7) |
- |
|
COPD |
5 (16.7) |
- |
|
Congestive heart failure |
3 (10.0) |
- |
|
Arrhythmia |
3 (10.0) |
- |
|
Seizure |
3 (10.0) |
- |
|
Myocardial infarction |
2 (6.7) |
- |
|
Cerebral vascular disease |
2 (6.7) |
- |
|
Solid tumor |
2 (6.7) |
- |
|
Neurodegenerative disease |
2 (6.7) |
- |
|
Liver disease |
1 (3.3) |
- |
|
Chronic kidney disease |
1 (3.3) |
- |
|
Drug or alcohol addiction |
1 (3.3) |
- |
|
Hematological disease |
1 (3.3) |
- |
|
Mood disorder |
1 (3.3) |
- |
Table 2.Blood gas analysis and hemodynamic parameters
|
Variable |
Value |
Range |
|
CO (L/min) |
6.1±1.1 |
4.2–8.7 |
|
PaO2 (mm Hg) |
113.0±26.3 |
71.0–180.0 |
|
PvO2 (mm Hg) |
50.0±6.4 |
37.0–65.0 |
|
PaCO2 (mm Hg) |
39.1±4.6 |
28.0–48.0 |
|
PvCO2 (mm Hg) |
45.5±5.3 |
35.0–58.0 |
|
SaO2 (%) |
99.7 (99.0–100.0) |
95.0–100.0 |
|
SvO2 (%) |
73.9 (70.5–76.7) |
60.0–80.5 |
|
Arterial HCO3– (mmol/L) |
25.4±6.0 |
14.5–41.0 |
|
Venous HCO3– (mmol/L) |
28.9±5.9 |
18.7–43.6 |
|
Hemoglobin (g/dl) |
9.8 (9.0–10.6) |
8.0–16.5 |
|
CaO2 (ml/dl) |
13.5 (12.5–14.8) |
11.2–22.7 |
|
CvO2 (ml/dl) |
9.9 (9.1–10.8) |
7.4–16.3 |
|
CaCO2 (ml/dl) |
26.5±6.1 |
15.5–42.3 |
|
CvCO2 (ml/dl) |
30.2±6.0 |
19.9–45.1 |
|
VO2 (ml/min) |
220.9±24.7 |
176.3–268.6 |
|
VCO2 (ml/min) |
215.1±23.1 |
159.0–265.9 |
|
RQ |
1.0 (0.9–1.0) |
0.8–1.2 |
Table 3.Correlation coefficients
|
Variable |
Bias between cREEHB and REEW
|
Bias between REEWB and REEW
|
|
Results (95% CI) |
P-value |
Results (95% CI) |
P-value |
|
Age |
–0.315 (–0.606 to 0.051) |
0.090 |
0.029 (–0.335 to 0.385) |
0.879 |
|
Height |
0.429 (0.081 to 0.684) |
0.018 |
0.260 (–0.110 to 0.567) |
0.165 |
|
Actual body weight |
0.351 (–0.011 to 0.631) |
0.057 |
0.594 (0.299 to 0.787) |
<0.001 |
|
BMI |
0.116 (–0.255 to 0.457) |
0.541 |
0.402 (0.049 to 0.666) |
0.027 |
|
BSA |
0.513 (0.188 to 0.737) |
0.004 |
0.660 (0.393 to 0.824) |
<0.001 |
|
Cardiac output |
0.149 (–0.223 to 0.483) |
0.432 |
0.114 (–0.257 to 0.456) |
0.548 |
|
PaO2
|
–0.121 (–0.461 to 0.250) |
0.523 |
–0.337 (–0.622 to 0.026) |
0.068 |
|
PvO2
|
0.172 (–0.200 to 0.501) |
0.363 |
–0.040 (–0.394 to 0.325) |
0.833 |
|
PaCO2
|
0.170 (–0.203 to 0.499) |
0.369 |
0.180 (–0.192 to 0.508) |
0.340 |
|
PvCO2
|
0.077 (–0.291 to 0.425) |
0.687 |
–0.024 (–0.381 to 0.339) |
0.898 |
|
SaO2 (%)a)
|
0.045 (–0.381 to 0.470) |
0.815 |
–0.089 (–0.525 to 0.348) |
0.639 |
|
SvO2 (%)a)
|
0.127 (–0.290 to 0.543) |
0.503 |
0.040 (–0.315 to 0.395) |
0.834 |
|
Arterial HCO3–
|
0.038 (–0.327 to 0.393) |
0.841 |
–0.131 (–0.469 to 0.240) |
0.490 |
|
Venous HCO3–
|
0.025 (–0.339 to 0.381) |
0.897 |
–0.163 (–0.494 to 0.210) |
0.390 |
|
Hemoglobina)
|
–0.299 (–0.680 to 0.086) |
0.109 |
–0.277 (–0.713 to 0.161) |
0.138 |
|
CaO2a)
|
–0.292 (–0.686 to 0.106) |
0.118 |
–0.272 (–0.717 to 0.174) |
0.145 |
|
CvO2a)
|
–0.228 (–0.639 to 0.186) |
0.226 |
–0.258 (–0.663 to 0.150) |
0.169 |
|
CaCO2
|
0.033 (–0.331 to 0.389) |
0.862 |
–0.127 (–0.466 to 0.245) |
0.504 |
|
CvCO2
|
0.011 (–0.350 to 0.370) |
0.952 |
–0.157 (–0.490 to 0.215) |
0.407 |
|
VO2
|
–0.436 (–0.688 to –0.089) |
0.016 |
–0.628 (–0.806 to –0.347) |
<0.001 |
|
VCO2
|
–0.141 (–0.477 to 0.231) |
0.458 |
–0.148 (–0.483 to 0.224) |
0.434 |
|
RQa)
|
0.409 (0.010 to 0.806) |
0.025 |
0.581 (0.305 to 0.853) |
<0.001 |
REFERENCES
- 1. Arabi YM, Casaer MP, Chapman M, Heyland DK, Ichai C, Marik PE, et al. The intensive care medicine research agenda in nutrition and metabolism. Intensive Care Med 2017;43:1239-56.ArticlePubMedPMCPDF
- 2. Singer P, Blaser AR, Berger MM, Alhazzani W, Calder PC, Casaer MP, et al. Espen guideline on clinical nutrition in the intensive care unit. Clin Nutr 2019;38:48-79.ArticlePubMed
- 3. WEIR JB. New methods for calculating metabolic rate with special reference to protein metabolism. J Physiol 1949;109:1-9.ArticlePubMedPMC
- 4. Vasileiou G, Mulder MB, Qian S, Iyengar R, Gass LM, Parks J, et al. Continuous indirect calorimetry in critically injured patients reveals significant daily variability and delayed, sustained hypermetabolism. JPEN J Parenter Enteral Nutr 2020;44:889-94.ArticlePubMedPDF
- 5. Lichter Y, Sold O, Angel Y, Nizri E, Gerstenhaber F, Gal Oz A, et al. Two-hour indirect calorimetry measurement as a predictor of 24-hour energy expenditure in critically ill surgical patients: A longitudinal study. JPEN J Parenter Enteral Nutr 2023;47:896-903.ArticlePubMed
- 6. Harris JA, Benedict FG. A biometric study of basal metabolism in man. Carnegie Institution of Washington; 1919.
- 7. Roza AM, Shizgal HM. The Harris benedict equation reevaluated: resting energy requirements and the body cell mass. Am J Clin Nutr 1984;40:168-82.ArticlePubMed
- 8. Frankenfield DC, Coleman A, Alam S, Cooney RN. Analysis of estimation methods for resting metabolic rate in critically ill adults. JPEN J Parenter Enteral Nutr 2009;33:27-36.ArticlePubMedPDF
- 9. Tatucu-Babet OA, Ridley EJ, Tierney AC. Prevalence of underprescription or overprescription of energy needs in critically ill mechanically ventilated adults as determined by indirect calorimetry: a systematic literature review. JPEN J Parenter Enteral Nutr 2016;40:212-25.ArticlePubMed
- 10. Fontaine E, Müller MJ. Adaptive alterations in metabolism: practical consequences on energy requirements in the severely ill patient. Curr Opin Clin Nutr Metab Care 2011;14:171-5.ArticlePubMed
- 11. Chada RR, Chidrawar S, Goud BA, Maska A, Medanki R, Nagalla B. Association Between Nutrition Delivery, Modified Nutrition Risk In Critically III Score, and 28-Day Mortality. Nutr Clin Pract 2021;36:1020-33.ArticlePubMedPDF
- 12. Dehmer GJ, Firth BG, Hillis LD. Oxygen consumption in adult patients during cardiac catheterization. Clin Cardiol 1982;5:436-40.ArticlePubMed
- 13. Noguchi H, Ogushi Y, Yoshiya I, Itakura N, Yamabayashi H. Breath-by-breath VCO2 and VO2 required compensation for transport delay and dynamic response. J Appl Physiol Respir Environ Exerc Physiol 1982;52:79-84.ArticlePubMed
- 14. Subramaniam A, McPhee M, Nagappan R. Predicting energy expenditure in sepsis: Harris-Benedict and Schofield equations versus the Weir derivation. Crit Care Resusc 2012;14:202-10.ArticlePubMed
- 15. Moore L, Lavoie A, Camden S, Le Sage N, Sampalis JS, Bergeron E, et al. Statistical validation of the Glasgow coma score. J Trauma 2006;60:1238-44.ArticlePubMed
- 16. Beck DH, Smith GB, Pappachan JV, Millar B. External validation of the saps ii, APACHE II and APACHE III prognostic models in South England: a multicentre study. Intensive Care Med 2003;29:249-56.ArticlePubMedPDF
- 17. Ferreira FL, Bota DP, Bross A, Mélot C, Vincent JL. Serial evaluation of the sofa score to predict outcome in critically ill patients. JAMA 2001;286:1754-8.ArticlePubMed
- 18. Pai MP, Paloucek FP. The origin of the "ideal" body weight equations. Ann Pharmacother 2000;34:1066-9.ArticlePubMedPDF
- 19. Yamada T, Tsutsui M, Sugo Y, Sato T, Akazawa T, Sato N, et al. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: a comparison with intermittent bolus thermodilution cardiac output. Anesth Analg 2012;115:82-7.ArticlePubMed
- 20. Sano H, Chambers JP. Ability of pulse wave transit time to detect changes in stroke volume and to estimate cardiac output compared to thermodilution technique in isoflurane-anaesthetised dogs. Vet Anaesth Analg 2017;44:1057-67.ArticlePubMed
- 21. Giavarina D. Understanding Bland Altman analysis. Biochem Med (Zagreb) 2015;25:141-51.ArticlePubMedPMC
- 22. Cohen J. Statistical power analysis for the behavioral sciences. Routledge; 2013.
- 23. Zusman O, Kagan I, Bendavid I, Theilla M, Cohen J, Singer P. Predictive equations versus measured energy expenditure by indirect calorimetry: a retrospective validation. Clin Nutr 2019;38:1206-10.ArticlePubMed
- 24. De Waele E, Opsomer T, Honoré PM, Diltoer M, Mattens S, Huyghens L, et al. Measured versus calculated resting energy expenditure in critically ill adult patients: do mathematics match the gold standard? Minerva Anestesiol 2015;81:272-82.ArticlePubMed
- 25. Hunter DC, Jaksic T, Lewis D, Benotti PN, Blackburn GL, Bistrian BR. Resting energy expenditure in the critically ill: estimations versus measurement. Br J Surg 1988;75:875-8.ArticlePubMedPDF
- 26. MacDonald A, Hildebrandt L. Comparison of formulaic equations to determine energy expenditure in the critically ill patient. Nutrition 2003;19:233-9.ArticlePubMed
- 27. Japur CC, Penaforte FR, Chiarello PG, Monteiro JP, Vieira MN, Basile-Filho A. Harris-Benedict equation for critically ill patients: are there differences with indirect calorimetry? J Crit Care 2009;24:628.e1-e5.ArticlePubMed
- 28. Graf S, Pichard C, Genton L, Oshima T, Heidegger CP. Energy expenditure in mechanically ventilated patients: the weight of body weight! Clin Nutr 2017;36:224-8.ArticlePubMed
- 29. Rousseau AF, Fadeur M, Colson C, Misset B. Measured energy expenditure using indirect calorimetry in post-intensive care unit hospitalized survivors: a comparison with predictive equations. Nutrients 2022;14:3981.ArticlePubMedPMC
- 30. Smetana KS, Hannawi Y, May CC. Indirect calorimetry measurements compared with guideline weight-based energy calculations in critically ill stroke patients. JPEN J Parenter Enteral Nutr 2021;45:1484-90.ArticlePubMedPDF
- 31. Pavlidou E, Petridis D, Tolia M, Tsoukalas N, Poultsidi A, Fasoulas A, et al. Estimating the agreement between the metabolic rate calculated from prediction equations and from a portable indirect calorimetry device: an effort to develop a new equation for predicting resting metabolic rate. Nutr Metab (Lond) 2018;15:41.ArticlePubMedPMCPDF
- 32. Saur J, Leweling H, Trinkmann F, Weissmann J, Borggrefe M, Kaden JJ. Modification of the Harris-Benedict equation to predict the energy requirements of critically ill patients during mild therapeutic hypothermia. In Vivo 2008;22:143-6.PubMed
- 33. Modra LJ, Higgins AM, Pilcher DV, Bailey MJ, Bellomo R. Sex differences in mortality of ICU patients according to diagnosis-related sex balance. Am J Respir Crit Care Med 2022;206:1353-60.ArticlePubMedPMC
- 34. Carrasco F, Reyes E, Núñez C, Riedemann K, Rimler O, Sánchez G, et al. Resting energy expenditure in obese and non-obese Chilean subjects: comparison with predictive equations for the Chilean population. Rev Med Chil 2002;130:51-60.PubMed
- 35. Ong CS, Brown P, Shou BL, Wilcox C, Cho SM, Mendez-Tellez PA, et al. Resting energy expenditure of patients on venovenous extracorporeal membrane oxygenation for adult respiratory distress syndrome: a pilot study. Crit Care Explor 2022;4:e0730. ArticlePubMedPMC
- 36. Brown HR, Pearson R. Demonstration of a positive relationship between cardiac output and oxygen consumption. Proc Soc Exp Biol Med 1947;65:307-9.ArticlePubMed
- 37. Peyton PJ. Carbon dioxide elimination and cardiac output changes. Intensive Care Med 2013;39:972.ArticlePubMedPDF
- 38. Permpikul C, Leelayuthachai T. Non-invasive estimated continuous cardiac output (escCO) during severe sepsis and septic shock resuscitation. J Med Assoc Thai 2014;97 Suppl 3:S184-8.PubMed
- 39. Sinha AC, Singh PM, Grewal N, Aman M, Dubowitz G. Comparison between continuous non-invasive estimated cardiac output by pulse wave transit time and thermodilution method. Ann Card Anaesth 2014;17:273-7.ArticlePubMed
- 40. Joshi M, Rathod R, Bhosale SJ, Kulkarni AP. Accuracy of estimated continuous cardiac output monitoring (esCCO) using pulse wave transit time (PWTT) compared to arterial pressure-based CO (APCO) measurement during major surgeries. Indian J Crit Care Med 2022;26:496-500.ArticlePubMedPMC
- 41. Taniguchi T, Fujii T, Takakura M, Nishiwaki K. Evaluation of the noninvasive estimated continuous cardiac output system for pediatric patients: a prospective observational study. Anesth Analg 2024 Sep 4 [Epub]. https://doi.org/10.1213/ANE.0000000000007144. Article
- 42. Takakura M, Fujii T, Taniguchi T, Suzuki S, Nishiwaki K. Accuracy of a noninvasive estimated continuous cardiac output measurement under different respiratory conditions: a prospective observational study. J Anesth 2023;37:394-400.ArticlePubMedPDF
Citations
Citations to this article as recorded by

- Interpreting Resting Energy Expenditure in Critically Ill Patients with Obesity: Clinical Impact of Weight Adjustment
Sebastián Chapela, Jaen Cagua-Ordoñez, Juan Marcos Parise-Vasco, Daniel Tettamanti Miranda, Claudia Kecskes, Natalia Llobera, Jesica Asparch, Mariana Rella, María Victoria Peroni, Martha Montalvan, María Jimena Reberendo, Facundo Gutierrez, Mario O. Pozo,
Journal of Clinical Medicine.2026; 15(5): 1677. CrossRef - Prediction is not precision: Predictive equations poorly predict resting energy expenditure in patients with peritoneal malignancy undergoing cytoreductive surgery and hyperthermic intraperitoneal chemotherapy
Lauren Reece, Morgan Brown, Kimberley Bostock, Jacelyn Moenting, Allysha Stibbard, Nabila Ansari, Nima Ahmadi, David L. Morris, Cherry Koh, Margaret Allman-Farinelli, Sharon Carey
Clinical Nutrition ESPEN.2026; 75: 105024. CrossRef - Correction: Estimating resting energy expenditure in critically ill patients: a retrospective exploratory comparison of predictive equations and Fick-derived Weir estimates in Italy
Antonio Romanelli, Alessandro Calicchio, Salvatore Palmese, Sabato Pascarella, Bruna Pisapia, Renato Gammaldi
Acute and Critical Care.2025; 40(4): 642. CrossRef - Response to “Correction and clarification on reported percentage error of estimated continuous cardiac output”
Antonio Romanelli, Alessandro Calicchio, Salvatore Palmese, Sabato Pascarella, Bruna Pisapia, Renato Gammaldi
Acute and Critical Care.2025; 40(4): 640. CrossRef - Correction and clarification on reported percentage error of estimated continuous cardiac output
Ryoichi Ochiai
Acute and Critical Care.2025; 40(4): 638. CrossRef - Phase-Related Resting Energy Expenditure in Critically Ill Adults: Metabolic Phenotypes and Determinants of Weight-Normalized Indices—A Retrospective Study
Sebastián Chapela, Jaen Cagua-Ordoñez, Jaime Angamarca-Iguago, Daniel Tettamanti, Claudia Kecskes, Jesica Asparch, Facundo Javier Gutierrez, Natalia Llobera, Mariana Rella, Martha Montalván, María Jimena Reberendo, Mario Omar Pozo, Ludwig Álvarez-Córdova,
Journal of Clinical Medicine.2025; 15(1): 237. CrossRef